Koyo DirectLogic PLC Password Brute Force Utility - Metasploit
This page contains detailed information about how to use the auxiliary/scanner/scada/koyo_login metasploit module. For list of all metasploit modules, visit the Metasploit Module Library.
Module Overview
Name: Koyo DirectLogic PLC Password Brute Force Utility
Module: auxiliary/scanner/scada/koyo_login
Source code: modules/auxiliary/scanner/scada/koyo_login.rb
Disclosure date: 2012-01-19
Last modification time: 2017-07-24 06:26:21 +0000
Supported architecture(s): -
Supported platform(s): -
Target service / protocol: -
Target network port(s): 28784
List of CVEs: -
This module attempts to authenticate to a locked Koyo DirectLogic PLC. The PLC uses a restrictive passcode, which can be A0000000 through A9999999. The "A" prefix can also be changed by the administrator to any other character, which can be set through the PREFIX option of this module. This module is based on the original 'koyobrute.rb' Basecamp module from DigitalBond.
Module Ranking and Traits
Module Ranking:
- normal: The exploit is otherwise reliable, but depends on a specific version and can't (or doesn't) reliably autodetect. More information about ranking can be found here.
Basic Usage
This module is a scanner module, and is capable of testing against multiple hosts.
msf > use auxiliary/scanner/scada/koyo_login
msf auxiliary(koyo_login) > show options
... show and set options ...
msf auxiliary(koyo_login) > set RHOSTS ip-range
msf auxiliary(koyo_login) > exploit
Other examples of setting the RHOSTS option:
Example 1:
msf auxiliary(koyo_login) > set RHOSTS 192.168.1.3-192.168.1.200
Example 2:
msf auxiliary(koyo_login) > set RHOSTS 192.168.1.1/24
Example 3:
msf auxiliary(koyo_login) > set RHOSTS file:/tmp/ip_list.txt
Required Options
- RHOSTS: The target host(s), range CIDR identifier, or hosts file with syntax 'file:<path>'
Go back to menu.
Msfconsole Usage
Here is how the scanner/scada/koyo_login auxiliary module looks in the msfconsole:
msf6 > use auxiliary/scanner/scada/koyo_login
msf6 auxiliary(scanner/scada/koyo_login) > show info
Name: Koyo DirectLogic PLC Password Brute Force Utility
Module: auxiliary/scanner/scada/koyo_login
License: Metasploit Framework License (BSD)
Rank: Normal
Disclosed: 2012-01-19
Provided by:
K. Reid Wightman <[email protected]>
todb <[email protected]>
Check supported:
No
Basic options:
Name Current Setting Required Description
---- --------------- -------- -----------
PREFIX A yes The prefix to use for the password (default: A)
RECV_TIMEOUT 3 no Time (in seconds) to wait between packets
RHOSTS yes The target host(s), range CIDR identifier, or hosts file with syntax 'file:<path>'
RPORT 28784 yes The target port (UDP)
THREADS 1 yes The number of concurrent threads (max one per host)
Description:
This module attempts to authenticate to a locked Koyo DirectLogic
PLC. The PLC uses a restrictive passcode, which can be A0000000
through A9999999. The "A" prefix can also be changed by the
administrator to any other character, which can be set through the
PREFIX option of this module. This module is based on the original
'koyobrute.rb' Basecamp module from DigitalBond.
References:
http://www.digitalbond.com/tools/basecamp/metasploit-modules/
Module Options
This is a complete list of options available in the scanner/scada/koyo_login auxiliary module:
msf6 auxiliary(scanner/scada/koyo_login) > show options
Module options (auxiliary/scanner/scada/koyo_login):
Name Current Setting Required Description
---- --------------- -------- -----------
PREFIX A yes The prefix to use for the password (default: A)
RECV_TIMEOUT 3 no Time (in seconds) to wait between packets
RHOSTS yes The target host(s), range CIDR identifier, or hosts file with syntax 'file:<path>'
RPORT 28784 yes The target port (UDP)
THREADS 1 yes The number of concurrent threads (max one per host)
Advanced Options
Here is a complete list of advanced options supported by the scanner/scada/koyo_login auxiliary module:
msf6 auxiliary(scanner/scada/koyo_login) > show advanced
Module advanced options (auxiliary/scanner/scada/koyo_login):
Name Current Setting Required Description
---- --------------- -------- -----------
CHOST no The local client address
CPORT no The local client port
ShowProgress true yes Display progress messages during a scan
ShowProgressPercent 10 yes The interval in percent that progress should be shown
VERBOSE false no Enable detailed status messages
WORKSPACE no Specify the workspace for this module
Auxiliary Actions
This is a list of all auxiliary actions that the scanner/scada/koyo_login module can do:
msf6 auxiliary(scanner/scada/koyo_login) > show actions
Auxiliary actions:
Name Description
---- -----------
Evasion Options
Here is the full list of possible evasion options supported by the scanner/scada/koyo_login auxiliary module in order to evade defenses (e.g. Antivirus, EDR, Firewall, NIDS etc.):
msf6 auxiliary(scanner/scada/koyo_login) > show evasion
Module evasion options:
Name Current Setting Required Description
---- --------------- -------- -----------
Go back to menu.
Related Pull Requests
- #8716 Merged Pull Request: Print_Status -> Print_Good (And OCD bits 'n bobs)
- #8338 Merged Pull Request: Fix msf/core and self.class msftidy warnings
- #6655 Merged Pull Request: use MetasploitModule as a class name
- #6648 Merged Pull Request: Change metasploit class names
- #5768 Merged Pull Request: Update modules to use metasploit-credential instead of report_auth_info
- #2525 Merged Pull Request: Change module boilerplate
- #1228 Merged Pull Request: MSFTIDY cleanup #1 - auxiliary
- #452 Merged Pull Request: Whitespace cleanup
References
See Also
Check also the following modules related to this module:
- auxiliary/scanner/scada/bacnet_l3
- auxiliary/scanner/scada/digi_addp_reboot
- auxiliary/scanner/scada/digi_addp_version
- auxiliary/scanner/scada/digi_realport_serialport_scan
- auxiliary/scanner/scada/digi_realport_version
- auxiliary/scanner/scada/indusoft_ntwebserver_fileaccess
- auxiliary/scanner/scada/modbus_banner_grabbing
- auxiliary/scanner/scada/modbusclient
- auxiliary/scanner/scada/modbusdetect
- auxiliary/scanner/scada/modbus_findunitid
- auxiliary/scanner/scada/moxa_discover
- auxiliary/scanner/scada/pcomclient
- auxiliary/scanner/scada/profinet_siemens
- auxiliary/scanner/scada/sielco_winlog_fileaccess
- auxiliary/admin/scada/advantech_webaccess_dbvisitor_sqli
- auxiliary/admin/scada/ge_proficy_substitute_traversal
- auxiliary/admin/scada/modicon_command
- auxiliary/admin/scada/modicon_password_recovery
- auxiliary/admin/scada/modicon_stux_transfer
- auxiliary/admin/scada/moxa_credentials_recovery
- auxiliary/admin/scada/multi_cip_command
- auxiliary/admin/scada/pcom_command
- auxiliary/admin/scada/phoenix_command
- auxiliary/admin/scada/yokogawa_bkbcopyd_client
- auxiliary/dos/scada/allen_bradley_pccc
- auxiliary/dos/scada/beckhoff_twincat
- auxiliary/dos/scada/d20_tftp_overflow
- auxiliary/dos/scada/igss9_dataserver
- auxiliary/dos/scada/siemens_siprotec4
- auxiliary/dos/scada/yokogawa_logsvr
- exploit/dialup/multi/login/manyargs
Authors
- K. Reid Wightman <wightman[at]digitalbond.com>
- todb
Version
This page has been produced using Metasploit Framework version 6.2.23-dev. For more modules, visit the Metasploit Module Library.