Siemens (CVE-2019-10943) - Nessus
High Plugin ID: 500055This page contains detailed information about the Siemens (CVE-2019-10943) Nessus plugin including available exploits and PoCs found on GitHub, in Metasploit or Exploit-DB for verifying of this vulnerability.
Plugin Overview
ID: 500055
Name: Siemens (CVE-2019-10943)
Filename: tenable_ot_siemens_CVE-2019-10943.nasl
Vulnerability Published: 2019-08-13
This Plugin Published: 2022-02-07
Last Modification Time: 2022-02-07
Plugin Version: 1.1
Plugin Type: remote
Plugin Family: Tenable.ot
Dependencies:
tenable_ot_api_integration.nasl
Required KB Items [?]: Tenable.ot/Siemens
Vulnerability Information
Severity: High
Vulnerability Published: 2019-08-13
Patch Published: 2019-08-13
CVE [?]: CVE-2019-10943
CPE [?]: cpe:/a:siemens:simatic_s7-1500_software_controller, cpe:/o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware, cpe:/o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware, cpe:/o:siemens:simatic_s7-1200_cpu_1211c_firmware, cpe:/o:siemens:simatic_s7-1200_cpu_1212c_firmware, cpe:/o:siemens:simatic_s7-1200_cpu_1214c_firmware, cpe:/o:siemens:simatic_s7-1200_cpu_1215c_firmware, cpe:/o:siemens:simatic_s7-1200_cpu_1217c_firmware, cpe:/o:siemens:simatic_s7-1500_cpu_1511c_firmware, cpe:/o:siemens:simatic_s7-1500_cpu_1512c_firmware, cpe:/o:siemens:simatic_s7-1500_cpu_1518_firmware
Synopsis
The remote OT asset is affected by a vulnerability.
Description
A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions <= 20.8), SIMATIC ET200SP (incl. SIPLUS variants) Open Controller CPU 1515SP PC (All versions), SIMATIC ET200SP (incl. SIPLUS variants) Open Controller CPU 1515SP PC2 (All versions), SIMATIC S7 PLCSIM Advanced (All versions <= V3.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions <= V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), excluding CPU 1518 MFP (and related SIPLUS variant) (All versions <= V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), excluding CPU 1518-4 PN/DP and CPU 1518 MFP (and related SIPLUS variant) (All versions <= V2.8.1), SIMATIC S7-1500 Software Controller (All versions <= V20.8). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device. No public exploitation of the vulnerability was known at the time of advisory publication.
This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.
Solution
Refer to the vendor advisory.
Public Exploits
Target Network Port(s): N/A
Target Asset(s): N/A
Exploit Available: True (GitHub)
Exploit Ease: Exploits (PoCs) are available
Here's the list of publicly known exploits and PoCs for verifying the Siemens (CVE-2019-10943) vulnerability:
- GitHub: https://github.com/ic3sw0rd/S7_plus_Crash
[CVE-2019-10943]
Before running any exploit against any system, make sure you are authorized by the owner of the target system(s) to perform such activity. In any other case, this would be considered as an illegal activity.
WARNING: Beware of using unverified exploits from sources such as GitHub or Exploit-DB. These exploits and PoCs could contain malware. For more information, see how to use exploits safely.
Risk Information
CVSS Score Source [?]: CVE-2019-10943
CVSS V2 Vector: AV:N/AC:L/Au:N/C:N/I:P/A:N
CVSS Base Score: | 5.0 (Medium) |
Impact Subscore: | 2.9 |
Exploitability Subscore: | 10.0 |
CVSS Temporal Score: | NA (None) |
CVSS Environmental Score: | NA (None) |
Modified Impact Subscore: | NA |
Overall CVSS Score: | 5.0 (Medium) |
CVSS Base Score: | 7.5 (High) |
Impact Subscore: | 3.6 |
Exploitability Subscore: | 3.9 |
CVSS Temporal Score: | NA (None) |
CVSS Environmental Score: | NA (None) |
Modified Impact Subscore: | NA |
Overall CVSS Score: | 7.5 (High) |
Go back to menu.
Plugin Source
This is the tenable_ot_siemens_CVE-2019-10943.nasl nessus plugin source code. This script is Copyright (C) 2022 and is owned by Tenable, Inc. or an Affiliate thereof.
#%NASL_MIN_LEVEL 70300
##
# (C) Tenable Network Security, Inc.
##
include('deprecated_nasl_level.inc');
include('compat.inc');
if (description)
{
script_id(500055);
script_version("1.1");
script_set_attribute(attribute:"plugin_modification_date", value:"2022/02/07");
script_cve_id("CVE-2019-10943");
script_name(english:"Siemens (CVE-2019-10943)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All
versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions <= 20.8), SIMATIC
ET200SP (incl. SIPLUS variants) Open Controller CPU 1515SP PC (All versions), SIMATIC ET200SP (incl. SIPLUS variants)
Open Controller CPU 1515SP PC2 (All versions), SIMATIC S7 PLCSIM Advanced (All versions <= V3.0), SIMATIC S7-1200 CPU
family (incl. SIPLUS variants) (All versions <= V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS
variants), excluding CPU 1518 MFP (and related SIPLUS variant) (All versions <= V2.8.1), SIMATIC S7-1500 CPU family
(incl. related ET200 CPUs and SIPLUS variants), excluding CPU 1518-4 PN/DP and CPU 1518 MFP (and related SIPLUS variant)
(All versions <= V2.8.1), SIMATIC S7-1500 Software Controller (All versions <= V20.8). An attacker with network access
to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from
the source code which is stored on the device. An attacker must have network access to affected devices and must be able
to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program
stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive
different source code that is not actually running on the device. No public exploitation of the vulnerability was known
at the time of advisory publication.
This plugin only works with Tenable.ot. Please visit
https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:P/A:N");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2019-10943");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_cwe_id(345);
script_set_attribute(attribute:"vuln_publication_date", value:"2019/08/13");
script_set_attribute(attribute:"patch_publication_date", value:"2019/08/13");
script_set_attribute(attribute:"plugin_publication_date", value:"2022/02/07");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1200_cpu_1211c_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1200_cpu_1212c_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1200_cpu_1214c_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1200_cpu_1215c_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1200_cpu_1217c_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_cpu_1518_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_cpu_1511c_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_cpu_1512c_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/a:siemens:simatic_s7-1500_software_controller");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2022 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware" : {},
"cpe:/o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware" :
{"versionEndExcluding" : "20.8"},
"cpe:/o:siemens:simatic_s7-1200_cpu_1211c_firmware" :
{"versionEndExcluding" : "4.4"},
"cpe:/o:siemens:simatic_s7-1200_cpu_1212c_firmware" :
{"versionEndExcluding" : "4.4"},
"cpe:/o:siemens:simatic_s7-1200_cpu_1214c_firmware" :
{"versionEndExcluding" : "4.4"},
"cpe:/o:siemens:simatic_s7-1200_cpu_1215c_firmware" :
{"versionEndExcluding" : "4.4"},
"cpe:/o:siemens:simatic_s7-1200_cpu_1217c_firmware" :
{"versionEndExcluding" : "4.4"},
"cpe:/o:siemens:simatic_s7-1500_cpu_1518_firmware" :
{"versionEndExcluding" : "2.8.1"},
"cpe:/o:siemens:simatic_s7-1500_cpu_1511c_firmware" :
{"versionEndExcluding" : "2.8.1"},
"cpe:/o:siemens:simatic_s7-1500_cpu_1512c_firmware" :
{"versionEndExcluding" : "2.8.1"},
"cpe:/a:siemens:simatic_s7-1500_software_controller" :
{"versionEndExcluding" : "20.8"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
The latest version of this script can be found in these locations depending on your platform:
- Linux / Unix:
/opt/nessus/lib/nessus/plugins/tenable_ot_siemens_CVE-2019-10943.nasl
- Windows:
C:\ProgramData\Tenable\Nessus\nessus\plugins\tenable_ot_siemens_CVE-2019-10943.nasl
- Mac OS X:
/Library/Nessus/run/lib/nessus/plugins/tenable_ot_siemens_CVE-2019-10943.nasl
Go back to menu.
How to Run
Here is how to run the Siemens (CVE-2019-10943) as a standalone plugin via the Nessus web user interface (https://localhost:8834/):
- Click to start a New Scan.
- Select Advanced Scan.
- Navigate to the Plugins tab.
- On the top right corner click to Disable All plugins.
- On the left side table select Tenable.ot plugin family.
- On the right side table select Siemens (CVE-2019-10943) plugin ID 500055.
- Specify the target on the Settings tab and click to Save the scan.
- Run the scan.
Here are a few examples of how to run the plugin in the command line. Note that the examples below demonstrate the usage on the Linux / Unix platform.
Basic usage:
/opt/nessus/bin/nasl tenable_ot_siemens_CVE-2019-10943.nasl -t <IP/HOST>
Run the plugin with audit trail message on the console:
/opt/nessus/bin/nasl -a tenable_ot_siemens_CVE-2019-10943.nasl -t <IP/HOST>
Run the plugin with trace script execution written to the console (useful for debugging):
/opt/nessus/bin/nasl -T - tenable_ot_siemens_CVE-2019-10943.nasl -t <IP/HOST>
Run the plugin with using a state file for the target and updating it (useful for running multiple plugins on the target):
/opt/nessus/bin/nasl -K /tmp/state tenable_ot_siemens_CVE-2019-10943.nasl -t <IP/HOST>
Go back to menu.
References
CWE | Common Weakness Enumeration:
- CWE-345 (Weakness) Insufficient Verification of Data Authenticity
- https://www.tenable.com/plugins/nessus/500055
- https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf
- https://vulners.com/nessus/TENABLE_OT_SIEMENS_CVE-2019-10943.NASL
- 500424 - Siemens (CVE-2014-0160)
- 500473 - Siemens (CVE-2014-0224)
- 500128 - Siemens (CVE-2014-2908)
- 500045 - Siemens (CVE-2014-5074)
- 500088 - Siemens (CVE-2015-2177)
- 500264 - Siemens (CVE-2015-5374)
- 500035 - Siemens (CVE-2015-5698)
- 500121 - Siemens (CVE-2016-8672)
- 500153 - Siemens (CVE-2016-8673)
- 500248 - Siemens (CVE-2018-3639)
- 500065 - Siemens (CVE-2019-12255)
- 500279 - Siemens (CVE-2019-12256)
- 500067 - Siemens (CVE-2019-12258)
- 500292 - Siemens (CVE-2019-12260)
- 500355 - Siemens (CVE-2019-13945)
- 500484 - Siemens (CVE-2020-15782)
- 500504 - Siemens (CVE-2021-3449)
- 500615 - Siemens (CVE-2021-37185)
- 500614 - Siemens (CVE-2021-37204)
- 500616 - Siemens (CVE-2021-37205)
- 63428 - Siemens Automation License Manager Multiple Vulnerabilities
- 85842 - Siemens SIMATIC S7-1200 PLC < 4.1.3 XSRF
- 47759 - Siemens SIMATIC WinCC Default Password Authentication Bypass
- 66839 - Siemens Solid Edge SEListCtrlX ActiveX Control SetItemReadOnly Method Memory Address Write Arbitrary Code Execution
- 66840 - Siemens Solid Edge WPHelper ActiveX Control OpenInEditor Method Arbitrary Command Execution
Version
This page has been produced using Nessus Professional 10.1.2 (#68) LINUX, Plugin set 202205072148.
Plugin file tenable_ot_siemens_CVE-2019-10943.nasl version 1.1. For more plugins, visit the Nessus Plugin Library.
Go back to menu.